{"id":577,"date":"2025-11-19T10:01:52","date_gmt":"2025-11-19T10:01:52","guid":{"rendered":"https:\/\/shiremedical.co.uk\/home\/?post_type=product&#038;p=577"},"modified":"2025-11-28T12:35:05","modified_gmt":"2025-11-28T12:35:05","slug":"remote-rtx","status":"publish","type":"product","link":"https:\/\/shiremedical.co.uk\/home\/product\/remote-rtx\/","title":{"rendered":"Remote RTX"},"content":{"rendered":"<p><strong>Features:<\/strong><br \/>\nConnection:<br \/>\nThe SDX-RTX transmitter links to the SDX-15 Alarm system via 2-core data bus cable.<br \/>\n4no input signals are wired from each gas (plant or manifold), via an end-of-line termination board, knowns as a TB4 PCB (optional).<br \/>\nEach gas requires upto a 5-core cable (4no switched conditions and 1no Common) and up to 4no gases can be in-putted via 1no SDX-RTX<\/p>\n<p>Maintenance:<br \/>\nTransmitter PCB requires a 230vac supply.<br \/>\nAll supply, input and data-bus terminations are via simple 45deg PCB mounted terminals.<\/p>\n<p>Application:<br \/>\nThe SDX-RTX is manufactured in a 1, 2, 3 or 4 channel (gas) variation, to suit the customers needs.<br \/>\nThese transmitters can also be upgraded to add or delete channels without the need to re-install new\/additional enclosures and supplies.<\/p>\n<p>The transmitter incorporates a single channel selector switch which determines the transmitted channel for the first gas (marked on the PCB as Service A). Where additional gases are required, the SDX-RTX will transmit as follows:<\/p>\n<p>Service A \u2013 Transmitted on channel selected by rotary switch (channel always used)<br \/>\nService B \u2013 Transmitted on channel selected by rotary switch plus 1, (used on one and two gas variations only)<br \/>\nService C \u2013 Transmitted on channel selected by rotary switch plus 2, (used on one, two and three gas variations only)<br \/>\nService D \u2013 Transmitted on channel selected by rotary switch plus 3, (used on four gas variation only)<\/p>\n<p>The SDX-RTX transmitter receives 4no analogue signals from up to 4no gases (plant or manifold) and then transmits these signals via a 2-core data-bus using Shire Controls own Medcon signal protocol. A single 2-core data-bus can transmit up to 60 status conditions (15no gases, each with up to 4no condition) and channels are determined via hexadecimal (16 way) rotary switches for transmitting (via SDX-15 transmitters) and receiving for display purposes (via SDX-15 Plant Alarms) or for interfacing to others (via SDX Computer Interfaces).<\/p>\n<p>For monitoring of input signal wiring, a termination box is required to be mounted as close as practical to the gas source. The integrity of the cabling between the gas source and the SDX-RTX is monitored, and a fault on this cable will result in visual system fault warning, with all affected alarm conditions going into alarm condition.<\/p>\n<p>Monitoring of the data-bus connection is always in operation. The transmitter looks to receive a strobe signal from the designated \u2018Central Panel\u2019 (the 24-hour monitored SDX-15 Plant Alarm), which ensures the system data-bus integrity. Any short-circuit, open-circuit or non-presence of a Central Panel will result in the transmitter giving a visual warning of this system fault.<\/p>\n<p>As the system is addressable, ALL SDX-15 system equipment (Alarms, Transmitters and Interfaces) can be added\/removed or relocated within the system. This simply requires the 2-core data-bus to be extended from the nearest existing SDX-15 Unit, or tee-ing off from a nearby existing cable run. Use 2-core screened cable (minimum 0.5mm).<\/p>\n<p>PCB LED Indicators:<br \/>\nSDX-RTX has 3 5mm round LED indicators \u2013 Green, Yellow and Red:<\/p>\n<ul>\n<li>Green \u2013 This LED shows that the 8vdc control voltage is present on the PCB. In order for this LED to be ON, the following are OK:<br \/>\nBoth the glass 315ma and 230vac 250ma ceramic fuses.<br \/>\nPCB transformer and rectifier circuit.<br \/>\n230vac is present.<\/li>\n<li>Red \u2013 This LED will be OFF if the system is functioning. The LED will flash if any of these occur:<br \/>\nThere is a short circuit anywhere on the 2-core data-bus cable.<br \/>\nThere is an open-circuit on the 2-core data bus cable between the designated \u2018Central Panel\u2019 and the SDX-RTX Transmitter.<br \/>\nThe designated \u2018Central Panel\u2019 has been switched off (i.e. has neither power nor battery back-up operating).<br \/>\nThe designated \u2018Central Panel\u2019 has is set-up as a \u2018Repeater\u2019 or the Control PCB has been unplugged.<\/li>\n<li>Yellow \u2013 This LED will be off if the system is functioning. The LED will flash if any unused input connections are NOT linked out to common via a 56K or 1K8 0.25watt resistor.<\/li>\n<\/ul>\n<p>Installation requirements:<br \/>\nA 230 vac supply, fused at 3 amps, fed from the essential supply<br \/>\nA 2-core screened cable (minimum 0.5mm) to SDX-15 data-bus.<br \/>\nA 5-core screened cable from each input gas connected (max. 4 gases).<br \/>\nAll screens to be earthed at BOTH ends.<\/p>\n<p>Equipment Warranty:<br \/>\nWarranty: alarms returned to our works which have failed due to faulty parts or manufacture will be repaired (or replaced) without charges for parts and labour.<br \/>\n10 year compatibility warranty: Install the SDX Plant Alarm System with the confidence that equipment will be available to modify or extend the system for at least 10 years.<\/p>\n<p>HTM 02-01 compliant<\/p>\n<p>Part Numbers:<br \/>\nWhen ordering, please specify the following format:<\/p>\n<p>SDXRTX x<\/p>\n<p>Where<br \/>\nx = number of gases (1, 2, 3 or 4)<br \/>\nIf possible, the hospital in which the alarm is to be installed.<\/p>\n","protected":false},"excerpt":{"rendered":"<div class=\"summary entry-summary\">\n<h1 class=\"product_title entry-title\">Remote RTX<\/h1>\n<div class=\"woocommerce-product-details__short-description\">\n<h4><strong>Class 1 Medical Device: Medical Gas Pipeline Systems<\/strong><br \/>\nFor more information &amp; documentation please\u00a0<a href=\"https:\/\/shiremedical.co.uk\/home\/contact-us\/\">Contact us.<\/a><\/h4>\n<p>&nbsp;<\/p>\n<p><strong><a href=\"https:\/\/shiremedical.co.uk\/wp-content\/uploads\/2025\/11\/IFU-SDXRTX-V1.0.pdf\" target=\"_blank\" rel=\"noopener\">RTX Manual 2024<\/a><\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"woocommerce-tabs wc-tabs-wrapper\">\n<p>&nbsp;<\/p>\n<\/div>\n","protected":false},"featured_media":348,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[24],"product_tag":[],"class_list":{"0":"post-577","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-transmitters","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/shiremedical.co.uk\/home\/wp-json\/wp\/v2\/product\/577","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shiremedical.co.uk\/home\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shiremedical.co.uk\/home\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shiremedical.co.uk\/home\/wp-json\/wp\/v2\/media\/348"}],"wp:attachment":[{"href":"https:\/\/shiremedical.co.uk\/home\/wp-json\/wp\/v2\/media?parent=577"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shiremedical.co.uk\/home\/wp-json\/wp\/v2\/product_brand?post=577"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shiremedical.co.uk\/home\/wp-json\/wp\/v2\/product_cat?post=577"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shiremedical.co.uk\/home\/wp-json\/wp\/v2\/product_tag?post=577"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}